How to adjust the amount of glue in the hot melt machine?
release time:2018-12-28 hit count:
Hot melt glue machine adjustment - there are two places, the key is the return valve. Here is a brief introduction to the hot melt machine return valve and how to adjust it:
The function of the return valve is to protect the gear pump and drive against overload operation of the system in an overpressure condition. The factory setting of 27 bar (400 psi) is the most suitable range, but can be adjusted according to different requirements.
How to adjust the hot melt machine return valve:
1. Check system equipment, hoses, and guns to ensure they are in an ideal equipment temperature state.
2. Loosen the lock nut that is attached to the adjustment screw of the return valve.
3. Turn the motor, refer to Chapter 5, and adjust the speed.
4. Open the gun valve to allow the adhesive to flow freely.
5. Turn off the gun valve to stop the flow of adhesive.
6. Until the ideal pressure is obtained, tighten the lock nut and the system completes the adjustment procedure.